Axia V1500A Touch Screen

$1.00 $0.00


Description

Axia V1500A Patient Monitor Features

The Axia V1500A patient monitor is designed for a fast-paced work environment. It offers standard measurements of NIBP, ECG, SpO2, Temperature, and Respiration. End-tidal CO2, Anesthetic Agent Measurement, Cardiac Output, and Invasive Blood Pressure can be added on-site by attaching plug-in modules. The V1500A has a 15-Inch high-resolution touchscreen monitor to optimize the speed of patient care.

  • 15-Inch touchscreen display.
  • Manage up to 72 hours of detailed patient data.
  • Easily upgradable from a basic vital signs monitor to a continuous bedside monitor, to an operating room monitor while keeping the patient on a single monitor at all times.
  • Offers Ethernet and RS-232 connections with open source communication protocol.
  • HL7 compliant.

Axia V1500A Patient Monitor Specifications

Applications

  • Neonatal
  • Pediatric
  • Adult Patients

Performance

  • Display: 15-inch color touchscreen
  • Trace: 8 waveforms
  • Indicator: Alarm indicator, Power indicator, QRS beep and alarm sound
  • Trend time: 1 – 72 hour
  • Recorder: Built-in, thermal array, 3 channels
  • Record width: 48mm
  • Recorder paper: 50mm
  • Record speed: 25mm/s, 50mm/s

ECG

  • Input: 5-lead ECG cable and standard AAMI line for connection
  • Lead Choice: I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
  • Gain Choice: x0.5, x1, x2, x4
  • Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
  • ECG Waveforms: 7 channels
  • Penetration Voltage: 4000VAC 50/60Hz
  • Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
  • HR Display Range: 30 ~ 300bpm
  • Accuracy: ±1bpm or ±1%, whichever is greater
  • Alarm Limit Range Setting: Upper Limit: 100 ~ 200bpm, Lower Limit: 30 ~ 100bpm

Respiration

  • Measure Method: RA-LL impedance
  • Range: 0 ~ 120 rpm
  • Accuracy: ±3 rpm
  • Alarm Limit Setting: Upper Limit 6 ~ 120 rpm, Lower Limit 3 ~ 120 rpm
  • Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)

Temperature

  • Range: 25 ~ 50 (°C)
  • Accuracy: ± 0.2°C (25.0 ~ 34.9°C); ± 0.1°C (35.0 ~ 39.9°C); ± 0.2°C (40.0 ~ 44.9°C); ± 0.3°C (45.0 ~ 50.0°C)
  • Display Resolution: 0.1°C
  • Alarm Limit Setting: Upper Limit 0 ~ 50°C, Lower Limit 0 ~ 50°C
  • Channel: 2 channels

NIBP

  • Measuring Technology: automatic oscillating measurement
  • Cuff Inflating: <30s (0 ~ 300 mmHg, standard adult cuff)
  • Measuring Period: AVE<40s
  • Mode: Manual, Auto
  • Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
  • Pulse Rate Range: 30 ~ 250 (bpm)
  • Measuring Range
    • Adult/Pediatric Mode: SYS: 40 ~ 250 (mmHg); DIA :15 ~ 200 (mmHg)
    • Neonatal Mode: SYS: 40 ~ 135 (mmHg); DIA : 15 ~ 100 (mmHg)
  • Accuracy
    • Maximum Mean error: ±5mmHg
    • Maximum Standard deviation: 8mmHg
    • Resolution: 1mmHg
    • Overpressure Protection: Adult Mode: 300 (mmHg)
    • Neonatal Mode: 160 (mmHg)
    • Alarm Limit Setting: SYS: 50 ~ 240 mmHg
    • DIA: 15 ~ 180 mmHg

SpO2 (Masimo)

  • Measurement range: 0% to 100%
  • Resolution: 1%
  • Accuracy
    • 70% to 100%, +/-2%, Adult/Pediatric, Non-motion conditions
    • 70% to 100%, +/-3%, Neonate, Nonmotion conditions
    • 70% to 100%, +/-3%, Adult/ Pediatric/Infant/Neonate, Motion conditions
    • 70% to 100%, +/-2%, Adult/ Pediatric/Infant/Neonate, Low perfusion conditions
  • Averaging time: 2~4 sec, 4~6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec (user selectable)
  • Sensitivity settings: Normal, Maximum, APOD (user selectable)

Pulse Rate

  • Measurement range: 25 to 240 bpm
  • Accuracy: +/-3 bpm, Adult/Pediatric/Infant/Neonate, Non-motion conditions 5 bpm, Adult/Pediatric/Infant/ Neonate, motion conditions
  • Resolution: 1 bpm

Perfusion Index (PI)

  • Measurement range: 0.02 – 20%

IBP

  • Measurement Range: -50 ~ 300mmHg
  • Channel: 2 channels
  • Pressure Transducer: sensitivity, 5µV/V/mmHg
  • Impedance Range: 300 ~ 3000Ω
  • Transducer Sites: ART, PA,CVP, RAP, LAP, ICP
  • Unit: mmHg/kPa selectable
  • Resolution: 1mmHg
  • Accurancy: ±1mmHg or ±2%, whichever is greater
  • Alarm Range: -10 ~ 300mmHg

EtCO2

  • CO2 Measurement Range: 0 ~ 99mmHg
  • Accuracy: ±2mmHg (0 ~ 38mmHg) 39-99mmHg ±5% of reading +0.08% for every 1mmHg (above 38mmHg)
  • Sampling Rate: 50 ml/min
  • Initialization Time: 30 seconds (typical), reaches ±5% steady-state accuracy within 3 minutes
  • Respiration Rate: 0 ~ 150 breaths/min
  • Mode: adult, neonate
  • Measurement Method: Thermodilution Method
  • Measurement Range
    • C.O. 0.1 to 20 L/min
    • TB 23 to 43℃
    • TI 0 to 27℃
  • Resolution
    • C.O. 0.1 L/min
    • TB, TI 0.1℃
  • Accuracy: C.O. ±5% or ±0.1 L/min, whichever is greater, as measured using electronically generated flow curves. TB, TI ±0.1 ℃(without sensor)
  • Alarm Range: TB 23 to 43℃
  • Repeatability: C.O. ±2% or ±0.1 L/min, whichever is greater, as measured using electronically generated flow curves

Anesthetic Agents

  • Method: Infrared absorption
  • Gas Sorts: Halothane, Isoflurane, Enflurane, Sevoflurane, Desflurane, CO2, N2O, O2 (optional Automatic Agent ID)
  • Measurement Range
    • Halothane, Isoflurane: 0 ~ 8.5%
    • Enflurane, Sevoflurane: 0 ~ 10%
    • Desflurane: 0 ~ 20%
    • CO2: 0 ~ 10%
    • N2O: 0 ~ 100%
    • O2: 0 ~ 100%
  • Bias
    • Halothane, Isoflurane, Enflurane, Sevoflurane, Desflurane: ±(0.15 Vol% + 15% rel.)
    • CO2: ±(0.5 Vol% + 12% rel.)
    • N2O: ± (2 Vol% + 8% rel.)
    • O2: ±3 Vol%

Networking

  • Industry standard 802.11b/g wireless network

Power

  • Source: External AC power or internal battery
  • AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
  • Battery: Built-in & rechargeable lithium ion
  • Operating Time: 3+ hours

Other Standard Features

  • OxyCRG, drug dose calculation, cascading ECG, On screen NIPB trends (up to 250 readings), user set defaults, Arrhythmia detection, ST segment

 