Shop

Datex Ohmeda Modulus SE Datex-Ohmeda
January 29, 2019
Mindray V21
January 29, 2019
Show all

Biolight BLT V6 Biolight

$1.00 $0.00


Description

Biolight BLT V6 Features

With the BLT V6 Vital Sign Monitor, lightweight vital sign monitoring has never been easier. The V6 contains a 7” color display for quick viewing of all parameters and easy visibility from a distance. The instant infra-red ear thermometer provides accurate temperature and includes one box of thermometer probe covers. A rechargeable (400ah) lithium-ion battery ensures worry-free transporting with long lasting battery life and compact design.

  • 7” color display
  • Parameters: (NIBP, Sp02, C02, Temp)
  • Recorder
  • Two-trace digital field
  • Hr/PR Sp02 NiBP (systolic, diastolic, & mean)
  • Screen display of alarm limits or disable status
  • Pr range 20 to 250 bpm
  • Sp02 0 – 100% display of plethysmograph
  • Pulse strength & Sp02 valves
  • NiBP range 10 to 270 mm hg accuracy +/- 3mm hg
  • Instant infrared ear thermometer w/ one box thermometer probe covers
  • Alarm setting for all parameters
  • 5000 group NiBP measurement data review
  • Rechargeable lithium-ion battery (4000 ah)r

Biolight BLT V6 Specifications

Dimensions

  • Size: 160x130x260mm (WxHxD)
  • Weight: (2.5 kg) (Including a lithium battery)
  • Display Size: 7” Color Anti-glare TFT LCD
  • Display Resolution: 234×480 pixels

Power

  • Input voltage: AC: 100V-240V, 50Hz/60Hz
  • Input power: 7OVA
  • Fuse: T1.6AU250V, 2-Φ5x20mm

Battery

  • Type: 11.1V 4000mAh rechargeable lithium ion battery
  • Operating time: >8 hours
  • Charge time: 6h to 100% (Standby)

Data Storage

  • Clinic Mode:
    • Patient quantity: 1000
    • Recording number: 16000
    • Single patient clinic record number: 1-16000
  • Monitor Mode:
    • Patient quantity: 1
    • Trend data:
      • Resolution 1 Min: Can store 96 hours
      • Resolution 5 Min: Can store 480 hours
      • Resolution 10 Min: Can store 960 hours
  • Alarm events: 1000
  • NIBP measurement record: 5000

Environmental

  • Operating
    • Temperature: (5~40) ℃
    • Humidity: ≤85% (noncondensing)
    • Atmospheric Pressure: (860~1060) hPa
  • Transportation and Storage
    • Temperature: (-20~+55)
    • Humidity : ≤93% (noncondensing)
    • Atmospheric Pressure: (500~1060) hPa

PR

  • Measurement range: 20~250 bpm
  • Resolution: 1 bpm
  • Accuracy: ±1 % or± 1 bpm, whichever is the greater

BLT Digital SpO2

  • Measurement range (0~100) %
  • Resolution: 1%
  • Accuracy: ± 2% (70%-100%); ± 3% (35%-69% )

Nellcor SpO2 (Option)

  • Measurement range (0~100) %
  • Resolution: 1%
  • Accuracy: ± 2% (70%~100%) (Adult); ± 3% (70%~100%) (Neonate); ± 2% (70%~100%) (Low Perfusion)

NIBP

  • Technique: Automaticoscillometry
  • Range:
    • Adult: 10-270mmHg
    • Child: 10-235mmHg
    • Neonate: 10-135mmHg
  • Accuracy: Static ±3 mm Hg
  • Clinic: Average error: ±5 mmHg
  • Standard Deviation: ≤8 mmHg
  • Unit: mmHg.kPa
  • Pulse Rate Range: 40-240 bpm

Microstream EtCO2 (Option)

  • Measurement way: Infrared spectrum
  • Measurement mode: sidestream
  • Sample Flow Rate: 50 ml/min± 10 ml/min
  • Measurement Range: (0-19.7) %, (0-150 mmHg)
  • Resolution: 0.1% or 1mmHg
  • Unit: %, mmHg, kPa
  • Accuracy:
    • ±2 mmHg O mmHg to 40 mmHg
    • ±5% of reading 41 mmHg to 70 mmHg
    • ±8% of reading 71 mmHg to 100 mmHg
    • ±10% of reading 101 mmHg to 150 mmHg
    • (760mmHg, temperature is 25 Degrees C)
    • (when RR >80 rpm, all the range is ±12% of reading)

 

Reviews (0)