Datascope Passport 2 ECG and Multiparameter Monitor Datascope

$1.00 $0.00


Description

More Datascope Passport 2 Pictures

Datascope Passport 2 Monitor - Soma Technology, Inc.Datascope Passport 2 - Soma Technology, Inc.Passport 2 - Soma Technology, Inc.

Datascope Passport 2 Features

The Passport 2 features an incredibly intelligent display interface which allows the user to evaluate patient status at a glance. Data is presented clearly, concisely and logically. Waveforms are aligned to digital data for immediate interpretation. Graph and list displays are easily configured to personal preference. The 4 Auto-Set Alarms program is quickly configured and extremely easy to use. Best of all, personalized custom settings retained on the PCMCIA cards assure super fast set-up.

Datascope Passport 2 Specifications

Dimensions

  • Monitor size: 9.5″H x 11.9″W x 7.4″D (24.1 cm x 30.2cm x 18.8cm)
  • Weight: 14.3 lbs. (6.5 kg) with 2 batteries.; 11.4 lbs. (5.2 kg) without batteries.

Battery requirements

  • 2 sealed lead acid batteries, 12 Vdc @ 2.3A load, 2.3 AH each battery.

Run time

  • 2 hours +/- 6 minutes from two fully charged batteries at 25°C with ECG SpO2 and 1 NIBP every 15 minutes, no recording, no CO2.
  • Recharge time: 16 hours maximum.

Power

  • AC voltage: 100-240 VAC +/-10% 50/60 Hz +/-3 Hz Single Phase.
  • Power consumption: 60-72 watts, 0.6-0.3 Amps.

Heart Rate Meter

  • Range: 30-300 bpm adult/ Pediatric, 30-350 bpm Neonate.
  • Accuracy: +/-3bpm or +/-3% at 30-250 bpm whichever is greater, +/-5% at 251-350 bpm.

IBP

  • Range: Sys/Dia/Mean: 30- +300 mmHg.
  • Accuracy: +/- 2 mmHg or 2% whichever is greater.
  • Scale: -10 to 10, 0-20, 0-40, 0-160, 0-225, 0-320, 60-140 mmHg.

NIBP

  • Technique: Oscillometric.
  • Connector type: Rectus.
  • Systolic range: adult: 55-235 mmHg, pediatric: 55-160 mmHg, neonate: 45-120 mmHg.
  • Diastolic range: adult: 30-220 mmHg, pediatric: 30-150 mmHg, neonate: 20-100 mmHg.
  • Systolic accuracy: mean error less that +/- 5 mmHg, standard deviation less than +/- 8 mmHg.
  • Diastolic accuracy: mean error less that +/- 5 mmHg, standard deviation less than +/- 8 mmHg.
  • Pulse rate range: adult/pediatric: 35 to 245 bpm, neonate: 70 to 245 bpm.
  • Pulse rate accuracy: +/-3 bpm or 3% whichever is greater.

Temperature

  • Scale: Selectable C° or F° Range: 15° to 45° C/ 59° to 113° F
  • Accuracy: +/- 0.1°C (15° C to 45° C); +/- 0.2° F (59° to 113° F) exclusive of probe errors.

Respiration

  • Range: 4 to 200 bpm.
  • Accuracy: +/-2% or 2 breaths per minute whichever is greater from 4 to 150 bpm, +/- 4% from 151 to 200 bpm.

CO2 (Microstream)

  • Range: 0-99 mmHg.
  • Accuracy: 0-38 mmHg +/-2 mmHg, 39-99 mmHg +/-5% +0.08% for every 1 mmHg above 40 mmHg.
  • Respiration rate: 0-150 bpm.
  • Respiration accuracy: +/- 1 breath per minute from 0-40 bpm, +/-2 bpm from 41-70 bpm, +/-3 bpm from 71-100 bpm, +/-5 bpm from 101-150 bpm.
  • ECG Leads: I, II, III, aVR, aVL, aVF, V.

Pulse Oximetry

  • SpO2 saturation accuracy with no motion conditions.
  • Adult / pediatric: 70 to 100% +/-2 digits SpO2, Neonate: 70 to 100% +/-3 digitsSpO2.
  • SpO2 saturation accuracy during motion.
  • Adult / pediatric / neonate: 70-100% +/-3 digits SpO2.

 