Drager Infinity Gamma XL

$1.00 $0.00


Description

Drager Infinity Gamma XL Features

The Infinity® Gamma and Gamma XL configured patient monitors, now with VF5 soft- ware functionality, provide a full set of the most commonly used parameters in a compact, user-friendly package. Because of the unique Pick and Go‚® capabilities, these monitors provide continuous surveillance while eliminating the need to purchase separate transport monitors. Patient data from both monitors is available either hardwired or wirelessl over the Infinity Network.

  • Provide monitoring versatility for any sub-acute care setting
  • Display 3 or 4 channels and offer a choice of sizes
  • Provide continuous monitoring and data collection

Drager Infinity Gamma XL Specifications

Monitoring Capabilities

  • Neonatal, pediatric and adult applications

ECG

  • Available leads
  • 3-lead set Leads: I, II, III
  • 5-lead set Leads: I, II, III, aVR, aVL, aVF, V
  • 6-lead set Leads: I, II, III, aVR, aVL, aVF, V, V+
  • Measuring range 15 to 300 bpm
  • Accuracy ± 5 bpm or ± 2% (whichever is greater)
  • Frequency range (± 3 db) 0.5 Hz to 28 Hz (50 Hz)
  • 0.5 Hz to 40 Hz (60 Hz)
  • Filter Frequency 50 to 60 Hz

QRS Detection Range

  • Alarms User-selectable upper and lower limits
  • Pacer detection Leads: I, II, or III
  • Amplitude: ± 5 to ± 700 mV
  • Separation between pulses: 30 msec
  • Width (dp): 0.1 to 2.0 msec
  • Accessories 3-, 5- or 6-lead electrode set

Dual Lead ST Analysis

  • Refer to ST datasheet 9049456

Respiration

  • Sensing lead II
  • Measuring method Impedance pneumography
  • Auxiliary current 10μA for any active electrode
  • Detection threshold 0.15 to 4.0 in manual mode (user adjustment)
  • Adult and pediatric: 0.20 to 10.5 in auto mode (automatic adjustment)
  • Neonatal: 0.20 to 1.5 in auto mode (automatic adjustment)
  • Measuring range 0 to 155 breaths/min
  • Accuracy ± 1 l/min or ± 2% (whichever is greater)
  • Alarms User-selectable upper and lower respiration rate

Pulse Oximetry (SpO2)

  • Displayed parameters Saturation (fraction of oxyhemoglobin to functional hemoglobin) and pulse (rate and curve)
  • Measuring method Absorption spectrophotometry
  • Pulse 15 to 300 bpm
  • Accuracy SpO2: 0 to 69% not specified
  • SpO2: 70 to 100% ± 2% (except ± 3% when using Nellcor® DS-100A and ± 3.5% when using Masimo® LNOP-Ear)
  • Saturation accuracy increases by ± 1 digit for neonates
  • Pulse: ± 3 bpm or ± 3% (whichever is less)
  • Alarms User-selectable upper and lower limits for SpO2 and pulse
  • Accessories Dräger Medical-approved Masimo and Nellcor sensors

Temperature

  • Displayed parameters Absolute temperature
  • Measuring range 0 to 50°C
  • Accuracy Probe: ± 0.1°C
  • System: ± 0.2°C
  • Alarms User-selectable upper and lower limits
  • Accessories Dräger Medical-approved core and skin probes

Noninvasive Blood Pressure (NBP)

  • Displayed parameters Systolic, mean and diastolic pressures
  • Measuring method Oscillometric utilizing step deflation

Modes of operation

  • Manual (single measurement) interval or continuous (5 minutes)
  • Interval times Off, 2, 2.5, 3, 5 (increments of 5),
  • 30, 45, 60, 120, 180, 240 minutes

Measuring range (default)

    • Adult (Adult 270 mmHg) (Adult 180 mmHg)

 

  • Heart rate 30 to 240 bpm 30 to 240 bpm
  • Systolic 30 to 250 mmHg 30 to 170 mmHg
  • Mean 20 to 230 mmHg 20 to 150 mmHg
  • Diastolic 10 to 210 mmHg 10 to 130 mmHg
  • Pediatric (Pediatric 180 mmHg) (Pediatric 140 mmHg)
  • Heart rate 30 to 240 bpm 30 to 240 bpm
  • Systolic 30 to 170 mmHg 30 to 130 mmHg
  • Mean 20 to 150 mmHg 20 to 110 mmHg
  • Diastolic 10 to 130 mmHg 10 to 130 mmHg
  • Neonatal (Neonatal 140 mmHg) (Neonatal 90 mmHg)
  • Heart rate 30 to 240 bpm 30 to 240 bpm
  • Systolic 30 to 130 mmHg 30 to 80 mmHg
  • Mean 20 to 110 mmHg 20 to 70 mmHg
  • Diastolic 10 to 100 mmHg 10 to 60 mmHg

 

Cuff pressure

  • Default inflation pressure Adult (270): 180 mmHg ± 5 mmHg
  • Pediatric (180): 130 mmHg ± 5 mmHg
  • Neonatal (140): 110 mmHg ± 5 mmHg
  • Adult (180): 130 mmHg ± 5 mmHg
  • Pediatric (140): 110 mmHg ± 5 mmHg
  • Neonatal (90): 80 mmHg ± 5 mmHg
  • Inflation pressure after a valid measurement (± 5 mmHg) Adult (270): Systolic + 25 mmHg
  • Pediatric (180): Systolic + 25 mmHg
  • Neonatal (140): Systolic + 30 mmHg
  • Adult (180): Systolic + 25 mmHg
  • Pediatric (140): Systolic + 30 mmHg
  • Neonatal (90): Systolic + 20 mmHg
  • Maximum inflation pressure Adult (270): 265 mmHg ± 5 mmHg
  • Pediatric (180): 180 mmHg ± 5 mmHg
  • Neonatal (140): 142 mmHg ± 5 mmHg
  • Adult (180): 180 mmHg ± 5 mmHg
  • Pediatric (140): 142 mmHg ± 5 mmHg
  • Neonatal (90): 80 mmHg ± 5 mmHg
  • Minimum inflation pressure Adult (270): 110 mmHg ± 5 mmHg
  • Adult (180): 90 mmHg ± 5 mmHg
  • Pediatric (180): 90 mmHg ± 5 mmHg
  • Pediatric (140): 70 mmHg ± 5 mmHg
  • Neonatal (both): 70 mmHg ± 5 mmHg
  • Connector Quick-release connector with single airway

 