GE MAC 5500 HD Features

The GE MAC 5500 HD Resting ECG System is a premier ECG machine that delivers advanced disease management capabilities through one of the industry-leading collections of algorithms and advanced networking. The MAC 5500 HD precisely captures, analyzes, and communicates ECG data. Sophisticated tools built on an easy-to-use design and platform enables clinicians to focus on what’s most important: their patients.

  • Better triaging tools for Acute Coronary Syndrome (ACS) detection.
  • Configurable Critical Values to help speed time to treatment.
  • More accurate pacemaker detection for advanced interpretation of paced rhythms.
  • Enhanced barcode workflow, with orders andADT download capability, work together to help improve efficiency across the enterprise.
  • Connected ECG Workflow to help save time and avoid costly misdiagnoses.
  • Advanced algorithms in ECG analysis and interpretation.

GE MAC 5500HD Specifications

Dimensions (Console)

  • Height: 3.7” (9.4 cm) (With display closed)
  • Width: 15” (38.1 cm)
  • Depth: 13.8” (35.1 cm)
  • Weight: 15 lbs (6.8 kg)

Dimensions (Cart)

  • Height: 37” (94 cm)
  • Width: 19” (47 cm)
  • Depth: 27” (69 cm)
  • Weight: 66 lbs (30 kg)

Display

  • Type: 10.4 in (264 mm) diagonal graphics backlit color AM LCD
  • Display Resolution: 640 x 480 pixels with waveform enhancement
  • Display Data: Heart rate, patient name, ID, clock, waveforms, lead labels, speed, gain and filter settings, warning messages, prompts, and help messages

Keyboard

  • Type: Sealed elastomer with soft function keys, alphanumeric keys, writer controls, and TrimPad cursor controls

Power

  • Power Supply: AC or battery operation
  • Voltage: 100 to 240 VAC
  • Current: 0.5A @ 115 VAC, 0.3A @ 240 VAC, typical, 0.85A max
  • Frequency: 50 to 60 Hz
  • Battery Type: User replaceable, 18V @ 3.5 AH ±10% rechargeable NiMH
  • Battery Capacity: 100 single page reports, (typical) or six hours continuous display (without printing)
  • Battery Charge Time: Approximately 4.5 hours from total discharge (with display off)

Environmental Operating Conditions

  • Temperature Range: 50°to 104° F (10° to 40° C)
  • Relative Humidity: 20% to 95% RH non-condensing
  • Atmospheric Pressure: 5700 to 1060 hPA

Environmental Storage Conditions

  • Temperature Range: –40°to 158° F (–40° to 70° C)
  • Relative Humidity: 15% to 95% RH non-condensing
  • Atmospheric Pressure: 500 to 1060 hP

Magnetic Card Reader

  • Character Set: ANSI/ISO ALPHA alphanumeric characters and ANSI/ISO BCD (subset of ASCII [ISO 646 IRV:1991])

Bar Code Scanner

  • Symbologies: Code 39 (extended), PDF-417, Code 128, Data Matrix, Interleaved 2 of 5

Processing

  • ECG Interpretation: Marquette* 12SL* ECG Analysis Program for Adults and Pediatrics
  • Computerized Measurements: 15-lead analysis includes measurements of user-selectable additional 3 leads
  • Optional: Hi-Res Late Potential Analysis and P-Wave Signal – Averaged ECG
  • Additional ECG Function: Vectorcardiography
  • ECG Analysis Frequency: 500 samples/second (sps)
  • ECG Storage: 200 ECGs in the internal memory
  • External Archiving: Secure Digital card
  • Digital Sampling Rate: 16,000 samples/second/channel
  • Pre-Acquisition: Provides 10 seconds of instantaneous ECG acquisition
  • Dynamic Range: AC Differential ± 5mV, DC offset ±300 mV
  • Resolution: 4.88 μV/LSB @ 250 sps, 4.88 μV/LSB @ 500 sps
  • Frequency Response: –3 dB @ 0.01 to 150 Hz
  • Common Mode Rejection: >140 dB (123 dB with AC filter disabled)
  • Input Impedance: >10MΩ @ 10 Hz, defibrillator protected
  • Patient Leakage: <10 μA
  • Pace Detection: Meets or exceeds ANSI/AAMI EC11-1991 standards
  • Pace Digital Sampling Rate: 75,000 samples / second / channel
  • Pace Pulse Width: as low as 0.2 ms in duration
  • Pace Pulse Amplitude: as low as 0.5 mV in amplitude
  • Special Acquisition Functions: Disconnected lead detection, electrode impedance, excessive AC noise, baseline wander, and muscle tremor messages
  • Heart Rate Meter: 30 to 300 BPM ±10% or 5 BPM, whichever is greater. Heart rates outside this range will not be displayed

Writer

  • Writer Technology: Thermal dot array
  • Writer Speeds: 5, 12.5, 25, and 50 mm/s
  • Number of Traces: 3, 6, 12, or 15 user selectable
  • Writer Sensitivity/Gain: 2.5, 5, 10, 20, 10/5 (split calibration) mm/mV
  • Writer Resolution: Horizontal 1000 dpi @ 25 mm/s, 200 dpi vertical
  • Paper Type: Thermal, Z-fold, perforated, fan fold, 300 sheets/pack
  • Paper Size: A Size: 8.5 in x 11 in, (214.6 mm x 280 mm)
  • A4 Size: 8.27 in x 11.7 in (210 mm x 297.5 mm)

 

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “GE MAC 5500 HD ECG System GE”

Your email address will not be published. Required fields are marked *